Cloud-Clone Corp.

ELISA Kit for Angiotensin I (AngI)

Product Code:
 
CEA811Hu
Product Group:
 
ELISA Kits
Supplier:
 
Cloud-Clone Corp.
Regulatory Status:
 
RUO
Target Species:
 
Human
Application:
 
Enzyme-Linked Immunosorbent Assay (ELISA)
1 / 1

No additional charges, what you see is what you pay! *

CodeSizePrice
CEA811Hu-24T24T£198.00
Quantity:
CEA811Hu-48T48T£324.00
Quantity:
CEA811Hu-96T96T£449.00
Quantity:
CEA811Hu-96T*596T*5£1,916.00
Quantity:
CEA811Hu-96T*1096T*10£3,592.00
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: China.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
  • Further Information
  • Documents
  • References
  • Show All

Further Information

Alternative Names:
Ang-I; Angiotensin-1
Assay length:
2h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Detection range:
12.35-1000pg/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Angiotensin I
Method:
Competitive Inhibition
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin I (AngI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin I (AngI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Endocrinology;Cardiovascular biology;Hepatology;Hormone metabolism;
Sample type:
Serum, plasma and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than 4.95pg/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of Angiotensin I (AngI).
No significant cross-reactivity or interference between Angiotensin I (AngI) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Angiotensin I (AngI) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Angiotensin I (AngI) and unlabeled Angiotensin I (AngI) (Standards or samples) with the pre-coated antibody specific to Angiotensin I (AngI). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Angiotensin I (AngI) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Angiotensin I (AngI) in the sample.
Uniprot ID:
P01019

References

https://doi.org/10.1016/j.genrep.2018.08.010;