Cloud-Clone Corp.

ELISA Kit for CUB Domain Containing Protein 1 (CDCP1)

Product Code:
 
SEB779Hu
Product Group:
 
ELISA Kits
Supplier:
 
Cloud-Clone Corp.
Regulatory Status:
 
RUO
Target Species:
 
Human
Application:
 
Enzyme-Linked Immunosorbent Assay (ELISA)
1 / 1

No additional charges, what you see is what you pay! *

CodeSizePrice
SEB779Hu-24T24T£207.00
Quantity:
SEB779Hu-48T48T£340.00
Quantity:
SEB779Hu-96T96T£473.00
Quantity:
SEB779Hu-96T*596T*5£2,021.00
Quantity:
SEB779Hu-96T*1096T*10£3,790.00
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: China.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
  • Further Information
  • Documents
  • References
  • Show All

Further Information

Alternative Names:
CD318; CDCP1; SIMA135; TRASK; Membrane glycoprotein gp140; Transmembrane and associated with src kinases; Subtractive immunization M plus HEp3-associated 135 kDa
Assay length:
3h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Detection range:
0.312-20ng/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
CUB Domain Containing Protein 1
Method:
Double-antibody Sandwich
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level CUB Domain Containing Protein 1 (CDCP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level CUB Domain Containing Protein 1 (CDCP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Tumor immunity;
Sample type:
Tissue homogenates, cell lysates and other biological fluids.
Sensitivity:
The minimum detectable dose of this kit is typically less than 0.124ng/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of CUB Domain Containing Protein 1 (CDCP1).
No significant cross-reactivity or interference between CUB Domain Containing Protein 1 (CDCP1) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to CUB Domain Containing Protein 1 (CDCP1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to CUB Domain Containing Protein 1 (CDCP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain CUB Domain Containing Protein 1 (CDCP1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of CUB Domain Containing Protein 1 (CDCP1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Uniport ID:
Q9H5V8

References

http://www.hbpdint.com/CN/abstract/abstract4525.shtml; https://www.researchsquare.com/article/rs-2274110/latest.pdf;