ProSci

IL-4 Antibody

Product Code:
 
PSI-XP-5188
Product Group:
 
Primary Antibodies
Supplier:
 
ProSci
Host Type:
 
Rabbit
Antibody Clonality:
 
Polyclonal
Regulatory Status:
 
RUO
Target Species:
 
Human
Applications:
  • Enzyme-Linked Immunosorbent Assay (ELISA)
  • Neutralisation
  • Western Blot (WB)
Storage:
 
IL-4 antibody is stable for at least 2 years from date of receipt at -20˚C. The reconstituted antibody is stable for at least two weeks at 2-8˚C. Frozen aliquots are stable for at least 6 months when stored at -20˚C. Avoid repeated freeze-t
1 / 4
To detect hIL-4 by sandwich ELISA (using 100 ul/well antibody solution) a concentration of 0.5 - 2.0 ug/ml of this antibody is required. This antigen affinity purified antibody, in conjunction with ProSci?s Biotinylated Anti-Human IL-4 (XP-5188Bt) as a detection antibody, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hIL-4.
2 / 4
To detect hIL-4 by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hIL-4 is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
3 / 4
To detect hIL-4 by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hIL-4 is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
4 / 4
This antibody stained formalin-fixed, paraffin-embedded sections of human breast invasive ductal carcinoma. The recommended concentration is 0.25 ug/mL with an overnight incubation at 4˚C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 6.0 sodium citrate buffer is recommended. Additional protein blocks were used in conjunction with the secondary reagents. Optimal concentrations and conditions may vary.

To detect hIL-4 by sandwich ELISA (using 100 ul/well antibody solution) a concentration of 0.5 - 2.0 ug/ml of this antibody is required. This antigen affinity purified antibody, in conjunction with ProSci?s Biotinylated Anti-Human IL-4 (XP-5188Bt) as a detection antibody, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hIL-4.
To detect hIL-4 by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hIL-4 is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
To detect hIL-4 by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hIL-4 is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
This antibody stained formalin-fixed, paraffin-embedded sections of human breast invasive ductal carcinoma. The recommended concentration is 0.25 ug/mL with an overnight incubation at 4˚C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 6.0 sodium citrate buffer is recommended. Additional protein blocks were used in conjunction with the secondary reagents. Optimal concentrations and conditions may vary.

No additional charges, what you see is what you pay! *

CodeSizePrice
PSI-XP-5188-0.1mg0.1mg£524.00
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: United States.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
  • Further Information
  • Documents
  • Show All

Further Information

Additional Names:
BSF1, IL-4, BCGF1, BSF-1, BCGF-1Interleukin-4, B-cell stimulatory factor 1
Application Note:
Neutralization:
To yield one-half maximal inhibition [ND50] of the biological activity of hIL-4 (1.50 ng/mL), a concentration of 0.06 -0.1 μg/mL of this antibody is required.

ELISA:

To detect hIL-4 by direct ELISA (using 100 μL/well antibody solution) a concentration of at least 0.5 μg/mL of this antibody is required. This antigen affinity purified antibody, in conjunction with compatible secondary reagents, allows the detection of 0.2 - 0.4 ng/well of recombinant hIL-4.

Sandwich:

To detect hIL-4 by sandwich ELISA (using 100 μL/well antibody solution) a concentration of 0.5 - 2.0 μg/mL of this antibody is required. This antigen affinity purified antibody, in conjunction with our Biotinylated Anti-Human IL-4 (XP-5188Bt) as a detection antibody, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hIL-4.

Western Blot:

To detect hIL-4 by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 μg/mL. Used in conjunction with compatible secondary reagents the detection limit for recombinant hIL-4 is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
Concentration:
batch dependent
Conjugate:
Unconjugated
Immunogen:
Produced from sera of rabbits pre-immunized with highly pure (>98%) recombinant hIL-4 (human Interleukin-4).
NCBI Gene ID #:
3565
NCBI Official Name:
interleukin 4
NCBI Official Symbol:
IL4
NCBI Organism:
Homo sapiens
Physical State:
Lyophilized
Protein Accession #:
P05112
Protein GI Number:
124337
Purification:
Anti-hIL-4 specific antibody was purified by affinity chromatography employing immobilized hIL-4 matrix.
Research Area:
Immunology,Chemokines & Cytokines,Antibody Pairs, Functional Assays
Swissprot #:
P05112
User NOte:
Centrifuge vial prior to opening.